Grate: Difference between revisions
| Line 51: | Line 51: | ||
===Incineration Air Feeding=== | ===Incineration Air Feeding=== | ||
Air is added at through various inlets in the [[Combustion|combustion]] chamber which is usually described as primary or secondary. Tertiary air and recirculated [[Flue | Air is added at through various inlets in the [[Combustion|combustion]] chamber which is usually described as primary or secondary. Tertiary air and recirculated [[Flue Gas|flue gases]] are used as well but are less common. Primary air is blown into areas below the [[Grate]] which cools the grate bar and caries oxygen into the [[Incineration|incineration]] bed. The secondary air is blown into the chamber to ensure complete [[Incineration|incineration]] of any [[Waste|waste]] left and intensive mixing of [[Flue Gas|flue gases]]. | ||
The main roles of the [[Incineration|incineration]] air: | The main roles of the [[Incineration|incineration]] air: | ||
| Line 57: | Line 57: | ||
*Cooling | *Cooling | ||
*Avoidance of slag formation | *Avoidance of slag formation | ||
*Mixing of [[Flue | *Mixing of [[Flue Gas|flue gases]] | ||
===Auxiliary Burners=== | ===Auxiliary Burners=== | ||