Veterinary Laboratories Agency: Difference between revisions

Bin52 (talk | contribs)
m update links
Bin52 (talk | contribs)
m degree symbol
Line 10: Line 10:
==Plant Description<ref name="Ref1" />==
==Plant Description<ref name="Ref1" />==
===Waste Reception & Storage===
===Waste Reception & Storage===
Waste is collected around the site in bins. These are transported to the [[Incineration|incinerator]] where a bin lift loads the waste in to the [[Incineration|incinerator]] by rotating the bins 180 degrees, this ensures all the contents fall out of the bin in to the waste feed hopper. The waste is injected into the [[Incineration|furnace]] by a ram.  Once inside the [[combustion]] chamber, rams move the waste through the [[grate]] at approximately 900<sup>o</sup>C thus promoting continuous mixing of the waste with the [[combustion]] air introduced from beneath the [[grate]] into the heart of the fire.  In the secondary chamber the gas temperature is maintained above 850<sup>o</sup>C for 2 seconds. [[IBA|Ash]] from the grate is discharged into a bespoke skip.   
Waste is collected around the site in bins. These are transported to the [[Incineration|incinerator]] where a bin lift loads the waste in to the [[Incineration|incinerator]] by rotating the bins 180 degrees, this ensures all the contents fall out of the bin in to the waste feed hopper. The waste is injected into the [[Incineration|furnace]] by a ram.  Once inside the [[combustion]] chamber, rams move the waste through the [[grate]] at approximately 900°C thus promoting continuous mixing of the waste with the [[combustion]] air introduced from beneath the [[grate]] into the heart of the fire.  In the secondary chamber the gas temperature is maintained above 850°C for 2 seconds. [[IBA|Ash]] from the grate is discharged into a bespoke skip.   


===Energy Recovery===
===Energy Recovery===
Hot gases from the [[combustion]] of waste pass through a waste heat steam boiler.  The temperature of the gases are reduced from over 850<sup>o</sup>C to around 160<sup>o</sup>C.  The gases heat up the water in the boiler and produce steam at 4.5barG.  This steam is fed to the site Energy Centre which distributes thermal energy around the site.  
Hot gases from the [[combustion]] of waste pass through a waste heat steam boiler.  The temperature of the gases are reduced from over 850°C to around 160°C.  The gases heat up the water in the boiler and produce steam at 4.5barG.  This steam is fed to the site Energy Centre which distributes thermal energy around the site.  


===Gas Cleaning===
===Gas Cleaning===