Revision as of 08:07, 15 August 2022


Widermerpool Biomass Power Plant
Operational
Site Location
Site Location

See Biomass EfW → page for a larger UK Wide map.

Operator Equitix ESI CHP (Nottingham) Ltd
Capacity 6.7 MWe
Feedstock Waste Wood
EPR (Waste Licence) QP3936AX
ROC Yes
CfD
CHP Yes

Operators Annual Report


Input Data

Year Wood Litter RDF Other Total
2018 25107 0 0 0 25107
2019 48730 0 0 0 48730
2020 53373 0 0 0 53373
2021 49199 0 0 0 49199
2022 49135 0 0 0 49135


Output Data

Year IBA IBA %ge of Tot IN APC APC %ge of Tot IN
2018 855 3.41% 269 1.07%
2019 1497 3.07% 468 0.96%
2020 2131 3.99% 617 1.16%
2021 1774 3.60% 662 1.34%
2022 2146 4.37% 600 1.22%


Summary

Plant

Annual Sustainability Tonnage Input/Fuel

The tonnage[1] received by the plant in the most recent Annual Sustainability Report and for the previous 3 years for 2020/21 was reported by Ofgem as below[2]:

Year Waste Wood (m3) Waste Wood (t) Straw Miscanthus Arboricultrual Waste Sawmill Residue Foresrty Residue Round Wood Short Rotation Coppice MBM Other Material
2020/21 0 40207 0 0 0 0 0 0 0 0 0
2019/20 0 45708 0 0 0 0 0 0 0 0 0
2018/19 0 29017 0 0 0 0 0 0 0 0 0
2017/18 0 0 0 0 0 0 0 0 0 0 0

Waste Tonnage, By Origin

The table shows a list of the Waste for the Permit QP3936AX, that has arrived into sites as reported to the Regulator and then publicised in their reported statistics. The Data was last updated on October 2024. The total reported tonnage arriving at the site was: 52,029.62t.

Where this tonnage exceeds that reported in year of the corresponding annual report, this may be due to the following reasons:

  • Tonnage may have been received but not incinerated, i.e. the material is held pending incineration (the operator return to the EA reports as received whereas the annual report focuses on when the waste is incinerated.)
  • Material may have been received into the site but treated in some other way than incineration.
  • Material may have been received on the but transferred out of site for disposal/treatment at another site rather than incineration on the site.
EWC Code Origin of Waste Tonnes In
19 12 07 Nottinghamshire 48438.40
19 12 07 Sheffield 3591.22


References

  1. In the case of EfW plants with gasification technology the figures are reported in terms of cubic metres of syngas produced rather than tonnes used
  2. Biomass Sustainability Dataset 2020-21