The formula for calculating the R1 status is given below:
The formula for calculating the R1 status is given below:


<big>P1 ef = (O<sub>exp</sub> - (E<sub>f</sub> + E<sub>imp</sub>))/(E<sub>f</sub> + E<sub>imp</sub> + E<sub>circ</sub>)</big>


[[File:R1 equation.png|frame|center|Equation to calculate the R1 status for efficiency]]<ref name="foo" />
all figures as equivalents in accordance to BREF,Chapter 3.5.6
 
 
 
 
 
 
 


*E<sub>f</sub>  = annual energy input to the system by fuels with steam production (GJ/y)
*E<sub>imp</sub> = annual imported energy (Note: energy from the treated waste (Ew) is not included)
*E<sub>circ</sub> = annual energy circulated
*O<sub>exp</sub> = annual exported energy (combined total of heat plus electricity as equivalents)


''"If the result is higher than 1: This shows that the plant minus imported energy with steam production is exporting (BREF) or producing (ECJ C-228/00) more energy than that which is required to operate the total waste incineration process."''<ref name="foo" />


[[File:R1 equation.png|frame|center|Equation to calculate the R1 status for efficiency]]<ref name="foo" />