R1 Recovery Facility: Difference between revisions

From Wikiwaste
MCWaste (talk | contribs)
Added caption for image
put formula inline
Line 11: Line 11:
The formula for calculating the R1 status is given below:
The formula for calculating the R1 status is given below:


<big>P1 ef = (O<sub>exp</sub> - (E<sub>f</sub> + E<sub>imp</sub>))/(E<sub>f</sub> + E<sub>imp</sub> + E<sub>circ</sub>)</big>


[[File:R1 equation.png|frame|center|Equation to calculate the R1 status for efficiency]]<ref name="foo" />
all figures as equivalents in accordance to BREF,Chapter 3.5.6
 
 
 
 
 
 
 


*E<sub>f</sub>  = annual energy input to the system by fuels with steam production (GJ/y)
*E<sub>imp</sub> = annual imported energy (Note: energy from the treated waste (Ew) is not included)
*E<sub>circ</sub> = annual energy circulated
*O<sub>exp</sub> = annual exported energy (combined total of heat plus electricity as equivalents)


''"If the result is higher than 1: This shows that the plant minus imported energy with steam production is exporting (BREF) or producing (ECJ C-228/00) more energy than that which is required to operate the total waste incineration process."''<ref name="foo" />


[[File:R1 equation.png|frame|center|Equation to calculate the R1 status for efficiency]]<ref name="foo" />


==References==
==References==
<references />
<references />

Revision as of 22:30, 25 November 2019

The R1 status of an Energy from Waste (EFW) facility determines whether that facility is regarded as Disposal or classifies it as an Energy Recovery Facility. The EU standard sets a requirement to meet high levels of power conversion efficiency to classify it as an R1 (and may need to be a CHP facility to fully meet the guidance).

To qualify as R1 status the EFW facility must :

Only R1 facilities can receive WDF from other EU countries for processing – export to other EU countries for Disposal (for example to an Incinerator that does not have R1 status) is illegal[2].

The formula for calculating the R1 status is given below:

P1 ef = (Oexp - (Ef + Eimp))/(Ef + Eimp + Ecirc)

all figures as equivalents in accordance to BREF,Chapter 3.5.6

  • Ef = annual energy input to the system by fuels with steam production (GJ/y)
  • Eimp = annual imported energy (Note: energy from the treated waste (Ew) is not included)
  • Ecirc = annual energy circulated
  • Oexp = annual exported energy (combined total of heat plus electricity as equivalents)

"If the result is higher than 1: This shows that the plant minus imported energy with steam production is exporting (BREF) or producing (ECJ C-228/00) more energy than that which is required to operate the total waste incineration process."[2]

File:R1 equation.png
Equation to calculate the R1 status for efficiency

[2]

References