ACT Efficiency: Difference between revisions
added formula as text rather than picture |
No edit summary |
||
Line 5: | Line 5: | ||
Where: | Where: | ||
*E<sub>products bio</sub> is the energy (MJ) from Biomass in the Advanced Fuel which is produced from the material to which E bio relates, | *E<sub>products bio</sub> is the energy (MJ) from Biomass in the Advanced Fuel which is produced from the material to which E<sub>bio</sub> relates, | ||
*E<sub>bio</sub> is the energy (MJ) from Biomass in the material from which the Advanced Fuel to which E products bio relates was produced; | *E<sub>bio</sub> is the energy (MJ) from Biomass in the material from which the Advanced Fuel to which E<sub>products bio</sub> relates was produced; | ||
*E<sub>inputs bio</sub> is any energy (MJ) used in the production of the Advanced Fuel to which E products bio relates. | *E<sub>inputs bio</sub> is any energy (MJ) used in the production of the Advanced Fuel to which E<sub>products bio</sub> relates. | ||
The ACT Efficiency must exceed the ACT Efficiency Standard of 60% over a specified amount of time known as the ACT Efficiency Period (typically weekly) in order to qualify for [[CfD]] support <ref>Department for Environment, Food and Rural Affairs (Defra), 2018. [https://assets.publishing.service.gov.uk/government/uploads/system/uploads/attachment_data/file/765494/ACT_Guidance_-_Compliance_with_the_ACT_Efficiency_Standard_criterion.pdf Guidance Note for Advanced Conversion Technologies Compliance with the ACT Efficiency Standard criterion in the Contract for Difference scheme. London.]</ref>. | The ACT Efficiency must exceed the ACT Efficiency Standard of 60% over a specified amount of time known as the ACT Efficiency Period (typically weekly) in order to qualify for [[CfD]] support <ref>Department for Environment, Food and Rural Affairs (Defra), 2018. [https://assets.publishing.service.gov.uk/government/uploads/system/uploads/attachment_data/file/765494/ACT_Guidance_-_Compliance_with_the_ACT_Efficiency_Standard_criterion.pdf Guidance Note for Advanced Conversion Technologies Compliance with the ACT Efficiency Standard criterion in the Contract for Difference scheme. London.]</ref>. |
Revision as of 09:50, 26 November 2019
In order to receive Contract for Difference support, the required ACT Efficiency of the conversion process must be met. The efficiency is calculated using the equation below:
ACT Efficiency = Eproducts bio / (Ebio + Einputs bio)
Where:
- Eproducts bio is the energy (MJ) from Biomass in the Advanced Fuel which is produced from the material to which Ebio relates,
- Ebio is the energy (MJ) from Biomass in the material from which the Advanced Fuel to which Eproducts bio relates was produced;
- Einputs bio is any energy (MJ) used in the production of the Advanced Fuel to which Eproducts bio relates.
The ACT Efficiency must exceed the ACT Efficiency Standard of 60% over a specified amount of time known as the ACT Efficiency Period (typically weekly) in order to qualify for CfD support [1].
References
- ↑ Department for Environment, Food and Rural Affairs (Defra), 2018. Guidance Note for Advanced Conversion Technologies Compliance with the ACT Efficiency Standard criterion in the Contract for Difference scheme. London.